ISO 11135 Process Validation: MPQ, PPQ & Routine Control

Process Validation · ISO 11135:2014 Published by Hangzhou Bocon | EO Sterilization Process Validation & Qualification Support An ISO 11135 process validation programme is not a single test. It is a chain: process definition, installation and operational qualification, then a performance qualification split into a microbiological and a physical half. Break one link and the

ISO 11135 Process Validation: MPQ, PPQ & Routine Control Read More »

ETO Sterilizer Operation & Maintenance SOP | Bocon

Standard Operating Procedure · ETO Sterilization Published by Hangzhou Bocon | Operation, Maintenance, Calibration & IQ/OQ/PQ Support This ETO sterilizer operation and maintenance SOP defines how an industrial ethylene oxide sterilizer is operated, maintained, calibrated and validated. It is the document referenced during operator training, routine audits and change control, and it keeps the original

ETO Sterilizer Operation & Maintenance SOP | Bocon Read More »

ETO Sterilizer FAT: What the Factory Test Must Prove Before Shipment

Supplier Qualification · Factory Acceptance Test Published by Hangzhou Bocon | ETO Sterilizer Manufacturing & Validation Support A factory acceptance test is the last moment when a chamber can still be corrected without a crane, a customs broker and a site shutdown. It is also the step buyers resource most thinly: one engineer travels, watches

ETO Sterilizer FAT: What the Factory Test Must Prove Before Shipment Read More »

How to Evaluate an ETO Sterilizer Manufacturer: 7 Engineering Checks

Supplier Qualification · ISO 11135 Published by Hangzhou Bocon | ETO Sterilizer Manufacturing & Station Engineering Most ETO sterilizer tenders are decided on chamber volume and price, then delivered by a company that owns neither the welding jig nor the control software. Seven engineering checks separate an ETO sterilizer manufacturer from an integrator before the

How to Evaluate an ETO Sterilizer Manufacturer: 7 Engineering Checks Read More »

ETO Sterilizer Sizes: 1–110 m³ Chamber Dimension Guide

Sizing Guide · ISO 11135 Published by Hangzhou Bocon | Industrial EO Sterilization Engineering & Validation Support Chamber volume is the first number every project team quotes and the last one that should be selected. For industrial ethylene oxide sterilizers, the practical decision starts with pallet count, door type, and the rooms on either side

ETO Sterilizer Sizes: 1–110 m³ Chamber Dimension Guide Read More »

ETO Sterilization FAQ: Packaging, Validation Cycles, IPCD & EPCD, Safety | HZBOCON

ETO Sterilization FAQ: Packaging, Validation Cycles, IPCD & EPCD, Safety | HZBOCON ETO Sterilization FAQ: Packaging, Validation Cycles, IPCD & EPCD, and Safety Published by Hangzhou Bocon | Ethylene Oxide Sterilization Engineering & Validation Support Ethylene oxide (EO) sterilization involves a complex interplay of packaging, load configuration, cycle design, and regulatory compliance. Even experienced professionals

ETO Sterilization FAQ: Packaging, Validation Cycles, IPCD & EPCD, Safety | HZBOCON Read More »

Sterile Gauze Shelf Life Explained: EO vs Steam Sterilization, Packaging Aging & Home Storage | HZBOCON

Sterile Gauze Shelf Life Explained: EO vs Steam Sterilization, Packaging Aging & Home Storage | HZBOCON Sterile Gauze Shelf Life Explained: EO vs Steam Sterilization, Packaging Aging & Home Storage Published by Hangzhou Bocon | Sterilization Technology & Medical Consumables Guide Sterile gauze is one of the most common medical consumables found in clinics, first-aid

Sterile Gauze Shelf Life Explained: EO vs Steam Sterilization, Packaging Aging & Home Storage | HZBOCON Read More »

ETO Sterilizer Microbial Inactivation Type Test | Half-Cycle Method & PCD

ETO Sterilizer Microbial Inactivation Performance Type Test | HZBOCON Validation Microbial Inactivation Performance Type Test for ETO Sterilizers Published by Hangzhou Bocon | Sterilization Validation & Performance Qualification The microbial inactivation type test is a critical performance qualification for ethylene oxide sterilizers, particularly for Class B equipment. This half‑cycle method uses process challenge devices (PCDs)

ETO Sterilizer Microbial Inactivation Type Test | Half-Cycle Method & PCD Read More »

ETO Sterilizer Chamber Leak Tightness Test | Negative & Positive Pressure Validation

ETO Sterilizer Chamber Leak Tightness Test | HZBOCON Validation Chamber Leak Tightness Test for Ethylene Oxide Sterilizers Published by Hangzhou Bocon | Industrial Sterilization Validation Solutions A properly sealed sterilization chamber is fundamental to maintaining the required ethylene oxide concentration and pressure conditions throughout the cycle. The following leak tightness tests are performed on an

ETO Sterilizer Chamber Leak Tightness Test | Negative & Positive Pressure Validation Read More »